Product Catalogue
Description

The sightseeing elevator installation conditions and technical requirements

2013/3/21 8:54:46

Weather conditions and outdoor sightseeing elevator

The sightseeing elevator can be installed in new buildings, internal or external, transformation projects for existing buildings can also be implemented. It is worth noting that The sightseeing elevator installed on the exterior of the building must meet specific criteria in order to withstand the adverse impact of the weather conditions at the installation location of the elevator equipment.

Posed a grave threat to the icing and frost generic load outdoor sightseeing elevators run. Insiders suggested in icing and frost occurs frequently place is not suitable for the installation of outdoor sightseeing elevator. Infrequent icing and frost event of icing and frost, the outdoor sightseeing ladder should stop using it. Windy weather may be a second reason people have to reduce outdoor sightseeing elevators running speed or stop elevator operation. The often windy place is not suitable for installation outdoor sightseeing ladder, unless the elevator shaft is located in the exterior of the building is completely sheltered position. Therefore, in this case, the building must be separately installed indoor elevator is very important, so that the weather conditions are not conducive to the the outdoor elevator operation, indoor elevator can still ensure that the vertical transportation without interruption.

Moderate rainfall, rainfall and hot weather does not constitute reasonable design, install good outdoor ladder hazards, but the natural causes of seasonal dust and blowing dust may cause excessive wear suitable equipment, the maintenance costs surge, which is in determining the building One of the problems before must consider whether to install an outdoor elevator. Exposed in the open elevator parts shall be treated as the appropriate treatment and protection.

The sightseeing lift the technical characteristics

The sightseeing elevator the traction drive or hydraulic drive may be used, their choice largely depends on the lift height and the building of the elevator hoistway conditions. Sightseeing elevator run high quality, usually using the the VVVF hydraulic drive way. The sightseeing elevator generally do not require high operating speed, because passengers want to stay for a while in the car to watch sedan outside landscape. Sightseeing elevator speed to a speed lower than the same object as appropriate, as long as it does not affect too slow vertical transport in buildings. Car sightseeing elevator car area consists of two parts, the passenger area and the scenic view. Adjacent to the passenger area and elevator hall door sedan, the viewing area is usually located at the rear of the car. Noteworthy is the surface area proportion of the viewing area and the passenger area must be suitable, the area will increase the proportion of the car balance of difficulty, due to the width of the passenger area of ​​the car is restricted to prolong the time of the passenger enters the car.

The sightseeing elevator novelty is in the the car viewing area using transparent viewing curtain wall. Before the Design sightseeing elevator car, the design building codes should be consulted in order to understand the requirements of the specifications for the use of glass materials in the elevator car and hoistway. In the design and installation process transparent the viewing curtain wall shall not be used as a load-bearing parts or structural components. Transparent the viewing curtain wall around the framework should be sufficient to withstand all levels of the force, including the elevator passengers may force without affecting safety performance occurred deformation.

Car top and bottom thereof of housing must be strong, but must also be light weight, easy to replace. Its design should ensure that the car external decorating the surface does not undermine repair jobs, oil or excessive lubricant.

Exposed portions and components

The surface of the car visible part of the external elevator landing door and its annexes exposure shall have a smooth, durable, corrosion resistant and easy cleaning surface. The surface of the material is generally steel or enamel corrosion resistant materials.

Elevator maintenance personnel to provide security jiaoding operation and traveling places it can be done, so that they can the jiaoding daily equipment maintenance and inspection. The day-to-day maintenance of equipment, including wells and cleaning of all public visual part and part, such as the landing door and door frame attachments. The sightseeing elevator car usually no emergency exit jiaoding. Bottomless pit underlying protection at the bottom of the elevator landing, the space below the hoistway should be isolated so that the elevator maintenance personnel can safely outside parts close to the bottom thereof, the implementation of routine maintenance and cleaning of Health, replacing the sedan and outdoor lighting and so on. Most important thing is to the hoistway pit wall must be set to prevent passengers or pedestrians straying into its inner. The usual practice is for the bottom of the hoistway and the elevator equipment decorating coordinated transparent curtain wall, which belongs to the elevator part of the civil work.



Next:The elevator maintenance

Previous:Do not ride no elevator Posted

SALES CONTACT Tel:+86-574-55849529
Contact Person:Joanna Zhou, Tina wu